[Back to NETWORK SWAG index] [Back to Main SWAG index] [Original]
{
Robert C. Kohlbus
I'm trying to compile and run a program that I wrote, with BP70
'real' mode, in 'Protected Mode'. This program uses Interrupt 21h
functions B80Xh and E3h, the Novell Netware ones. The program worked fine
in 'real' mode, but gives incorrect information in 'Protected Mode'. After
calling Borland, they said it was because the DPMI overlay file didn't know
how to handle the interrupts I was trying to access. They suggested that I
look at a file from their BBS called READWRTE.PAS that shows how to handle
interrupts in a 'Protected Mode' program. Basically this example file, just
interrupt 31h (Simulate Real Mode Interrupt). My problem is that my program
continues to hang up, even after following their example. Below is a sample
part of my program. If anyone can lend a hand, I would be in their debt.
}
Program Getid; { Get unique Id for Novell Netware Bindery Object }
uses
Dos, Crt, WinApi;
type
TDPMIRegs = record
edi, esi, ebp, reserved, ebx, edx, ecx, eax: LongInt;
flags, es, ds, fs, gs, ip, cs, sp, ss : Word;
end;
var
Hexid : string;
R: TDPMIRegs;
RequestBuffer : record
PacketLength : integer;
functionval : byte;
ObjectType : packed array [1..2] of byte;
NameLength : byte;
ObjectName : packed array [1..47] of char;
end;
ReplyBuffer : record
ReturnLength : integer;
UniqueID1 : packed array [1..2] of byte;
UniqueID2 : packed array [1..2] of byte;
ObjectType : packed array [1..2] of byte;
ObjectName : packed array [1..48] of byte;
end;
function DPMIRealInt(IntNo, CopyWords: Word; var R: TDPMIRegs): Boolean; assembler;
asm
mov ax, 0300h
mov bx, IntNo
mov cx, CopyWords
les di, R
int 31h
jc @error
mov ax, 1
jmp @done
@error:
xor ax, ax
@Done:
end;
function LongFromBytes(HighByte, LowByte: Byte): LongInt; assembler;
asm
mov dx, 0
mov ah, HighByte
mov al, LowByte
end;
function LongFromWord(LoWord: Word): LongInt; assembler;
asm
mov dx, 0
mov ax, LoWord;
end;
function RealToProt(P: Pointer; Size: Word; var Sel: Word): Pointer;
begin
SetSelectorBase(Sel, LongInt(HiWord(LongInt(P))) Shl 4 + LoWord(LongInt(P)));
SetSelectorLimit(Sel, Size);
RealToProt := Ptr(Sel, 0);
end;
procedure GetObjectID(Name : string; ObjType : Word);
const
HEXDIGITS : Array [0..15] of char = '0123456789ABCDEF';
var Reg : Registers;
i : integer;
Hex_ID, S : string;
ErrorCode : word;
ObjectId : array[1..8] of byte;
begin
with RequestBuffer do
begin
PacketLength := 52;
FunctionVal := $35;
ObjectType[1] := $0;
ObjectType[2] := ObjType;
NameLength := length(Name);
for i := 1 to length(Name) do
ObjectName[i] := Name[i];
end;
ReplyBuffer.ReturnLength := 55;
{ Original Code that worked in Real Mode }
{
Reg.ah := $E3;
Reg.ds := seg(RequestBuffer);
Reg.si := ofs(RequestBuffer);
Reg.es := seg(ReplyBuffer);
Reg.di := ofs(ReplyBuffer);
MsDos(Reg);
}
{ New Code From Borland Example }
FillChar(R, SizeOf(TDPMIRegs), #0);
R.Eax := $E3;
R.ds := seg(RequestBuffer);
R.Esi := LongFromWord(ord(RequestBuffer));
R.es := seg(ReplyBuffer);
R.Edi := LongFromWord(ord(ReplyBuffer));
DPMIRealInt($21, 0, R);
{
S := 'None';
Errorcode := Reg.al;
if Errorcode = $96 then S := 'Server out of memory';
if Errorcode = $EF then S := 'Invalid name';
if Errorcode = $F0 then S := 'Wildcard not allowed';
if Errorcode = $FC then S := 'No such object *'+QueueName+'*';
if Errorcode = $FE then S := 'Server bindery locked';
if Errorcode = $FF then S := 'Bindery failure';
S := 'Error : '+ S;
Writeln(S);
}
Hex_ID := '';
Hex_ID := hexdigits[ReplyBuffer.UniqueID1[1] shr 4];
Hex_ID := Hex_ID + hexdigits[ReplyBuffer.UniqueID1[1] and $0F];
Hex_ID := Hex_ID + hexdigits[ReplyBuffer.UniqueID1[2] shr 4];
Hex_ID := Hex_ID + hexdigits[ReplyBuffer.UniqueID1[2] and $0F];
Hex_ID := Hex_ID + hexdigits[ReplyBuffer.UniqueID2[1] shr 4];
Hex_ID := Hex_ID + hexdigits[ReplyBuffer.UniqueID2[1] and $0F];
Hex_ID := Hex_ID + hexdigits[ReplyBuffer.UniqueID2[2] shr 4];
Hex_ID := Hex_ID + hexdigits[ReplyBuffer.UniqueID2[2] and $0F];
while Hex_ID[1] = '0' do
Hex_ID := copy(Hex_ID,2,length(Hex_ID));
Hexid := Hex_ID;
end;
begin
Hexid := '';
ClrScr;
{ Get An Objects Id
Parameters (2) Object Name, Object Type
Object Name = String[8];
Object Type = Word;
1 User
2 User Group
3 Print Queue
4 File Server
5 Job Server
6 Gateway
7 Print Server
}
GetObjectID('BUSINESS', 3); { Get Print Queue's ID }
Writeln('Hexid for BUSINESS is ',hexid);
end.
[Back to NETWORK SWAG index] [Back to Main SWAG index] [Original]