Unit ScrUnit;
Interface
Const
MaxPages = 20;
Type
PageType = Array [1..50,1..80] Of Word;
PageArray = Array [1..MaxPages] Of ^PageType;
Var
Screen : ^PageType;
ScrPages : PageArray;
PageInMem : Array [1..MaxPages] Of Boolean;
VideoMode : ^Byte;
UseDisk : Boolean;
Procedure InitPages(Pages : Byte);
Procedure DeInitPages;
Procedure StoreScreen(Page : Byte);
Procedure RestoreScreen(Page : Byte);
Implementation
{$IFNDEF VER70}
Const Seg0040 = $0040;
SegB000 = $B000;
SegB800 = $B800;
{$endIF}
Var
MPages : Byte;
SaveExitProc : Pointer;
Function FStr(Num : LongInt) : String;
Var Dummy : String;
begin
Str(Num,Dummy);
FStr := Dummy;
end;
Procedure InitPages;
Var
Loop : Byte;
begin
If Pages>MaxPages Then
Pages := MaxPages;
For Loop:=1 To Pages Do
If (MaxAvail>=SizeOf(PageType)) And (Not UseDisk) Then
begin
PageInMem[Loop] := True;
GetMem(ScrPages[Loop],SizeOf(PageType));
end
Else
begin
PageInMem[Loop] := False;
ScrPages[Loop] := NIL;
end;
MPages := Pages;
end;
Procedure DeInitPages;
Var Loop : Byte;
begin
If MPages>0 Then
For Loop:=MPages DownTo 1 Do
If PageInMem[Loop] Then
begin
Release(ScrPages[Loop]);
PageInMem[Loop] := False;
end;
MPages := 0;
end;
Procedure StoreScreen;
Var
F : File Of PageType;
begin
If Page<=MPages Then
begin
If PageInMem[Page] Then
Move(Screen^,ScrPages[Page]^,SizeOf(PageType))
Else
begin
Assign(F,'SCR'+FStr(Page)+'.$$$');
ReWrite(F);
If IOResult=0 Then
begin
Write(F,Screen^);
Close(F);
end;
end;
end;
end;
Procedure RestoreScreen;
Var
F : File Of PageType;
begin
If Page<=MPages Then
begin
If PageInMem[Page] Then
Move(ScrPages[Page]^,Screen^,SizeOf(PageType))
Else
begin
Assign(F,'SCR'+FStr(Page)+'.$$$');
Reset(F);
If IOResult=0 Then
begin
Read(F,Screen^);
Close(F);
end;
end;
end;
end;
{$F+}
Procedure ScreenExitProc;
Var
Loop : Byte;
F : File;
begin
ExitProc := SaveExitProc;
If MPages>0 Then
For Loop:=1 To MPages Do
begin
Assign(F,'SCR'+FStr(Loop)+'.$$$');
Erase(F);
If IOResult<>0 Then;
end;
end;
{$F-}
begin
VideoMode := Ptr(Seg0040,$0049);
If VideoMode^=7 Then
Screen := Ptr(SegB000,$0000)
Else
Screen := Ptr(SegB800,$0000);
MPages := 0;
UseDisk := False;
SaveExitProc := ExitProc;
ExitProc := @ScreenExitProc;
end.
(*
This simple Unit is able to store up to 20 screens. If there is enough free
heap all screens are stored to heap which is Really fast. If there is not
enough free heap or UseDisk=True all screens are stored virtually to disk. This
method isn't very fast, of course, but it helps you to save heap.
Use this Unit as follows:
Program ThisIsMyProgram;
Uses Screen;
begin
InitPages(5); { initialize 5 pages }
{...} { this is on you }
end.
*)
[Back to SAVESCRN SWAG index] [Back to Main SWAG index] [Original]